In reality however, you can reach an ISO 6 cleanroom with 1 recommendation is 2 airlock. Again, it depends of the size of the room, the process taking place inside the cleanroom, the number of people working inside, the equipment inside, etc.
Unidirectional air flow is sometimes recommended to reach ISO 6 classification. For a room of less than 4—6 meters in width depending on the activities taking place inside the cleanroom , air returns can be positioned on the side of the walls instead of in the floor.
Installing air returns in the floor is more expensive. In reality, however, you can reach an ISO 5 cleanroom with 2 or 3 airlocks. The optimal layout depends on the process taking place inside the cleanroom, the size of the room, the number of people working inside, the equipment inside, etc. In addition, an ISO 5 or class clean room needs to use unidirectional air flow.
Unidirectional air flow cleanrooms use much more air than non-directional air flow cleanrooms. High efficiency filters are installed across the entire ceiling. The filtered air sweeps down the room in a unidirectional way, at a velocity generally between 0. Cleanrooms using unidirectional air flow are more expensive than non-unidirectional ones, but can comply with more stringent classifications, such as ISO 5 or lower.
ISO 5 Nanofabrication cleanroom facility. As stated before, clean rooms are classified by how clean the air is, according to the number of particles and size of particles per volume of air. Some classifications do not require certain particle sizes to be tested because the respective concentrations are too low or too high to be tested, but they should not be zero. For ISO 7, particles smaller than 0. Air cleanliness is achieved by passing the air through HEPA filters using flow principles such as laminar flow.
The more often the air passes through the HEPA filters, the fewer particles are left in the room air. The volume of air filtered in one hour divided by the volume of the room gives the number of air changes per hour. The above-suggested air changes per hour are only a design rule of thumb. They should be computed by an HVAC clean room expert, as many aspects must be taken into consideration, such as the size of the room, the number of people in the room, the equipment in the room, the processes involved, the heat gain, etc.
Contact our experts to discuss your project. Please note that this information is only provided for educational purposes. The definitions in this article are oversimplified in order to assist with understanding. This article will not help you decide which clean room classification you must reach. If help is needed in this respect, seek the advice of an expert in your industry pharmaceutical, medical devices, sterile compounding, electronics, etc.
We can Design-Build-Install and Commission your cleanroom or we can partner with other professionals that your are currently working with! By continuing to use the site you agree to our privacy policy.
Clean Room Classifications Clean rooms are classified according to the cleanliness level of the air inside the controlled environment. ISO Cleanroom Standards and layouts Depending on the class of clean room system you would like to reach, it is important to allow for enough square footage. Cleanroom classification and air changes per hour Air cleanliness is achieved by passing the air through HEPA filters using flow principles such as laminar flow.
The ambient air outside in a typical city environment contains 35,, particles per cubic meter, 0. Cleanrooms are used in practically every industry where small particles can adversely affect the manufacturing process. They vary in size and complexity, and are used extensively in industries such as semiconductor manufacturing, pharmaceuticals, biotech, medical device and life sciences, as well as critical process manufacturing common in aerospace, optics, military and Department of Energy.
A cleanroom is any given contained space where provisions are made to reduce particulate contamination and control other environmental parameters such as temperature, humidity and pressure. Personnel selected to work in cleanrooms undergo extensive training in contamination control theory. Depending on the room classification or function, personnel gowning may be as limited as lab coats and hairnets, or as extensive as fully enveloped in multiple layered bunny suits with self contained breathing apparatus.
Cleanroom clothing is used to prevent substances from being released off the wearer's body and contaminating the environment. The cleanroom clothing itself must not release particles or fibers to prevent contamination of the environment by personnel.
This type of personnel contamination can degrade product performance in the semiconductor and pharmaceutical industries and it can cause cross-infection between medical staff and patients in the healthcare industry for example.
The type of cleanroom garments used should reflect the cleanroom and product specifications. Low-level cleanrooms may only require special shoes having completely smooth soles that do not track in dust or dirt.
However, shoe bottoms must not create slipping hazards since safety always takes precedence. A cleanroom suit is usually required for entering a cleanroom. Class 10, cleanrooms may use simple smocks, head covers, and booties. For Class 10 cleanrooms, careful gown wearing procedures with a zipped cover all, boots, gloves and complete respirator enclosure are required.
Laminar, or unidirectional, air flow systems direct filtered air downward in a constant stream. Proper cleanroom design encompasses the entire air distribution system, including provisions for adequate, downstream air returns.
In vertical flow rooms, this means the use of low wall air returns around the perimeter of the zone.